<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CEREGLIDE | STELLANEWS.LIFE</title>
	<atom:link href="https://stellanews.life/tag/cereglide/feed/" rel="self" type="application/rss+xml" />
	<link>https://stellanews.life</link>
	<description>ヘルスケアのニュースを医療専門の編集者とAI（人工知能）の力で毎日届ける。</description>
	<lastBuildDate>Thu, 05 Mar 2026 11:17:50 +0000</lastBuildDate>
	<language>ja</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://stellanews.life/wp-content/uploads/2025/05/cropped-cropped-stellanewslogo-32x32.webp</url>
	<title>CEREGLIDE | STELLANEWS.LIFE</title>
	<link>https://stellanews.life</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>J&#038;J、虚血性脳卒中向け吸引カテーテルCEREGLIDE 42／57とデリバリー補助INNERGLIDE 7を米国発売</title>
		<link>https://stellanews.life/medicaldevice/9005/</link>
					<comments>https://stellanews.life/medicaldevice/9005/#respond</comments>
		
		<dc:creator><![CDATA[ステラ・メディックス]]></dc:creator>
		<pubDate>Thu, 05 Mar 2026 11:16:04 +0000</pubDate>
				<category><![CDATA[循環器]]></category>
		<category><![CDATA[救急・集中治療]]></category>
		<category><![CDATA[治療機器・手術支援]]></category>
		<category><![CDATA[神経]]></category>
		<category><![CDATA[CEREGLIDE]]></category>
		<category><![CDATA[INNERGLIDE]]></category>
		<category><![CDATA[Johnson & Johnson]]></category>
		<category><![CDATA[医療機器]]></category>
		<category><![CDATA[吸引カテーテル]]></category>
		<category><![CDATA[神経血管デバイス]]></category>
		<category><![CDATA[脳血管内治療]]></category>
		<category><![CDATA[虚血性脳卒中]]></category>
		<category><![CDATA[血栓回収]]></category>
		<guid isPermaLink="false">https://stellanews.life/article/9005/</guid>

					<description><![CDATA[<p>STELLANEWS.LIFE（ステラニュース・ライフ）は、科学や技術、医薬品や医療機器分野で発表される最新情報を継続的に収集し、臨床現場に関わる論点を整理して伝えることに特化したメディアである。今回の記事で伝える情報は [&#8230;]</p>
<p>The post <a href="https://stellanews.life/medicaldevice/9005/">J&J、虚血性脳卒中向け吸引カテーテルCEREGLIDE 42／57とデリバリー補助INNERGLIDE 7を米国発売</a> first appeared on <a href="https://stellanews.life">STELLANEWS.LIFE</a>.</p>]]></description>
										<content:encoded><![CDATA[<article class="sn-article" itemscope itemtype="https://schema.org/Article" itemid="#article">
<p>  <!-- リード（説明文：本文外） --></p>
<p id="lead" class="sn-lead" itemprop="description">
    STELLANEWS.LIFE（ステラニュース・ライフ）は、科学や技術、医薬品や医療機器分野で発表される最新情報を継続的に収集し、臨床現場に関わる論点を整理して伝えることに特化したメディアである。今回の記事で伝える情報は次の通り。
  </p>
<p>  <!-- 本文 --><br />
  <main id="content" class="sn-body" itemprop="articleBody"></p>
<p>    <!-- 要点 --></p>
<div class="ab-card ab-soft ab-accent ab-keypoints" id="keypoints" data-section="keypoints" aria-label="要点">
<div class="ab-title">要点</div>
<ul class="ab-kp-list">
<li class="ab-kp-item">Johnson &amp; Johnsonが、虚血性脳卒中の吸引血栓回収向けにCEREGLIDE 42、CEREGLIDE 57、INNERGLIDE 7を米国で発売した。</li>
<li class="ab-kp-item">末梢側（リリース脚注ではM2）への到達性、システム互換性、吸引力、手技の簡素化を狙う「マルチアキシャル」構成として説明された。</li>
<li class="ab-kp-item">可変剛性、親水性コーティング、透視下マーカーなどの設計要素を提示する一方、一部主張はベンチ/前臨床根拠であり、臨床成績の比較データは示されていない。</li>
</ul></div>
<p>    <!-- 概要 --></p>
<section id="summary" class="sn-section sn-summary" aria-labelledby="summary-title" data-section="summary">
<h2 id="summary-title">概要</h2>
<p>　Johnson &amp; Johnsonは2026年2月26日、虚血性脳卒中の血栓回収に用いる吸引カテーテル「CEREGLIDE 42」「CEREGLIDE 57」と、デリバリー補助デバイス「INNERGLIDE 7」を米国で発売したと発表した。CEREGLIDEシリーズは42、57、71の吸引カテーテルで構成され、吸引ファースト戦略に対応するポートフォリオ拡充として位置付けられている。</p>
<p>　血栓回収は短時間で進む一方、末梢側閉塞や屈曲血管では到達性と操作性の両立が課題になりやすい。複数カテーテルを組み合わせる手技では、内径/外径の適合や交換操作の煩雑さが手技時間や安全性に影響し得る。</p>
<p>　発表では、CEREGLIDE 42/57の可変剛性構造、親水性コーティング、透視下マーカーなどの設計要素と、シリーズ全体の互換性をそろえる意図が示された。INNERGLIDE 7は太径カテーテルを末梢側へ進める際のデリバリー補助として説明され、親水性コーティングシャフト、1.5cmの柔らかい遠位端、0.024インチガイドワイヤー互換などが挙げられている。</p>
<p>　ただし本発表は製品発売の情報であり、臨床成績の比較データは示されていない。末梢到達性の改善は有用性と同時に血管損傷などの合併症リスク評価も重要となるため、実臨床での成績は今後のデータ蓄積で確認が必要となる。</p>
</section>
<p>    <!-- 詳細 --></p>
<div class="ab-card" id="details" data-section="details" aria-label="詳細">
<div class="ab-title">詳細</div>
<ul class="ab-meta">
<li><strong>発表元</strong><span>Johnson &amp; Johnson</span></li>
<li><strong>発表日</strong><span>2026年2月26日</span></li>
<li><strong>製品</strong><span>CEREGLIDE 42、CEREGLIDE 57、INNERGLIDE 7</span></li>
<li><strong>領域</strong><span>脳血管内治療／虚血性脳卒中の血栓回収（吸引）</span></li>
<li><strong>用途の位置付け</strong><span>吸引ファーストの血栓回収に用いる吸引カテーテル（CEREGLIDE 42/57）とデリバリー補助（INNERGLIDE 7）</span></li>
<li><strong>ポートフォリオ</strong><span>CEREGLIDEシリーズは42、57、71で構成</span></li>
<li><strong>想定ターゲット</strong><span>末梢側血栓（脚注で末梢側＝M2と記載）</span></li>
<li><strong>CEREGLIDE 42/57の設計要素</strong><span>可変剛性（variable-stiffness）構造で末梢側の追従性と近位側の支持性の両立を狙う</span></li>
<li><strong>表面処理</strong><span>親水性コーティングにより屈曲血管での摩擦低減を意図</span></li>
<li><strong>視認性</strong><span>透視下での視認性を意図したマーカー（ベンチ試験に基づく記載を含む）</span></li>
<li><strong>ワークフロー</strong><span>シリーズ間の互換性をそろえ、適合確認や意思決定の負担を減らす意図（発表内の説明）</span></li>
<li><strong>INNERGLIDE 7の目的</strong><span>太径カテーテル（例：CEREGLIDE 71）を末梢側へ進める際のデリバリー補助</span></li>
<li><strong>INNERGLIDE 7の仕様要素</strong><span>親水性コーティングシャフト、1.5cmソフト遠位端、0.024インチガイドワイヤー互換</span></li>
<li><strong>根拠の種類</strong><span>一部はベンチ試験・前臨床試験に基づく記載で、臨床結果を直接示すものではない</span></li>
<li><strong>安全性観点</strong><span>到達性向上は有用性と同時に血管損傷など合併症リスク評価も重要。臨床データと施設運用の蓄積が鍵</span></li>
</ul></div>
<p>    <!-- AI評価 --></p>
<section class="sn-section sn-impact" aria-labelledby="impact" data-section="impact">
<h2 id="impact">AIによるインパクト評価</h2>
<p><strong>評価（参考）：</strong> ★★★☆☆</p>
<p>　末梢側への到達性や互換性の改善を狙った新製品投入は、現場の手技設計とワークフローに影響し得る。一方で本発表は発売情報で、臨床成績の比較データは示されていない。実装上の価値は、実臨床での到達性・手技時間・合併症（血管損傷等）を含む運用成績の蓄積で評価される。</p>
</section>
<p>    <!-- 多言語要約 --></p>
<section id="intl-keypoints" class="sn-section sn-intl" aria-labelledby="intl-keypoints-title" data-section="intl-keypoints">
<h2 id="intl-keypoints-title">3言語要約 / Multilingual Summaries</h2>
<section class="sn-intl-block" lang="en" aria-labelledby="en-summary-title">
<h3 id="en-summary-title">English Summary</h3>
<p class="translate-note">Note: AI-assisted translation for reference.</p>
<ul>
<li>Johnson &amp; Johnson launched CEREGLIDE 42 and CEREGLIDE 57 aspiration catheters and the INNERGLIDE 7 delivery-assist device in the U.S. for ischemic stroke thrombectomy.</li>
<li>The company describes the system as a multi-axial setup aimed at distal access (noted as M2), compatibility across components, and workflow simplification.</li>
<li>Design features cited include variable stiffness, hydrophilic coating, and fluoroscopic markers; some claims are based on bench/preclinical testing, and no comparative clinical outcomes were presented.</li>
</ul>
<p>        <meta itemprop="inLanguage" content="en"><br />
      </section>
<section class="sn-intl-block" lang="zh" aria-labelledby="zh-summary-title">
<h3 id="zh-summary-title">中文摘要</h3>
<p class="translate-note">注：AI辅助生成。</p>
<ul>
<li>强生在美国推出用于缺血性卒中吸引取栓的CEREGLIDE 42、CEREGLIDE 57吸引导管以及INNERGLIDE 7递送辅助器械。</li>
<li>公司将其描述为“多轴”系统，旨在改善远端（脚注提及M2）到达性、器械兼容性并简化操作流程。</li>
<li>所述特点包括可变刚度、亲水涂层及透视标记；部分主张基于台架/前临床试验，未提供对照临床结局数据。</li>
</ul>
<p>        <meta itemprop="inLanguage" content="zh"><br />
      </section>
<section class="sn-intl-block" lang="hi" aria-labelledby="hi-summary-title">
<h3 id="hi-summary-title">हिन्दी सारांश</h3>
<p class="translate-note">AI द्वारा तैयार किया गया अनुवाद।</p>
<ul>
<li>Johnson &amp; Johnson ने इस्केमिक स्ट्रोक थ्रोम्बेक्टॉमी के लिए CEREGLIDE 42/57 aspiration कैथेटर और INNERGLIDE 7 delivery-assist डिवाइस को अमेरिका में लॉन्च किया।</li>
<li>कंपनी के अनुसार यह multi-axial सिस्टम distal (फुटनोट में M2) access, component compatibility और workflow simplification को लक्षित करता है।</li>
<li>डिज़ाइन फीचर्स में variable stiffness, hydrophilic coating और fluoroscopic markers शामिल बताए गए; कुछ दावे bench/preclinical डेटा पर आधारित हैं और comparative clinical outcomes प्रस्तुत नहीं किए गए।</li>
</ul>
<p>        <meta itemprop="inLanguage" content="hi"><br />
      </section>
</section>
<p>  </main></p>
<p>  <!-- 参考文献 --></p>
<div class="ab-card ab-accent sn-refs" id="references" data-section="references" aria-label="参考文献">
<div class="ab-title">参考文献</div>
<p>
      Johnson &amp; Johnson Completes Catheter Portfolio with Launch of CEREGLIDE 42, CEREGLIDE 57, and INNERGLIDE 7<br />
      <a href="https://www.jnj.com/media-center/press-releases/johnson-johnson-completes-catheter-portfolio-with-launch-of-cereglide-42-cereglide-57-and-innerglide-7" rel="nofollow noopener" target="_blank"><br />
        https://www.jnj.com/media-center/press-releases/johnson-johnson-completes-catheter-portfolio-with-launch-of-cereglide-42-cereglide-57-and-innerglide-7<br />
      </a>
    </p>
<p>    <meta itemprop="keywords" content="虚血性脳卒中, 血栓回収, 吸引カテーテル, CEREGLIDE, INNERGLIDE, 脳血管内治療, M2, 医療機器, Johnson &#038; Johnson"><br />
    <meta itemprop="articleSection" content="Medical Devices / Neurointervention / Stroke">
  </div>
</article><p>The post <a href="https://stellanews.life/medicaldevice/9005/">J&J、虚血性脳卒中向け吸引カテーテルCEREGLIDE 42／57とデリバリー補助INNERGLIDE 7を米国発売</a> first appeared on <a href="https://stellanews.life">STELLANEWS.LIFE</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://stellanews.life/medicaldevice/9005/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>J&#038;JがSNIS 2025で片頭痛への塞栓術や新型カテーテルを紹介</title>
		<link>https://stellanews.life/technology/6477/</link>
					<comments>https://stellanews.life/technology/6477/#respond</comments>
		
		<dc:creator><![CDATA[ステラ・メディックス]]></dc:creator>
		<pubDate>Sat, 19 Jul 2025 19:55:51 +0000</pubDate>
				<category><![CDATA[技術]]></category>
		<category><![CDATA[CEREGLIDE]]></category>
		<category><![CDATA[J&J MedTech]]></category>
		<category><![CDATA[Johnson & Johnson]]></category>
		<category><![CDATA[SNIS 2025]]></category>
		<category><![CDATA[TRUFILL n-BCA]]></category>
		<category><![CDATA[マイクロカテーテル]]></category>
		<category><![CDATA[中硬膜動脈塞栓術]]></category>
		<category><![CDATA[塞栓療法]]></category>
		<category><![CDATA[慢性片頭痛]]></category>
		<category><![CDATA[片頭痛]]></category>
		<category><![CDATA[神経血管内治療学会]]></category>
		<category><![CDATA[神経血管治療]]></category>
		<category><![CDATA[血栓除去カテーテル]]></category>
		<guid isPermaLink="false">https://stellanews.life/?p=6477</guid>

					<description><![CDATA[<p>STELLANEWS.LIFE（ステラニュース・ライフ）は、医療、科学、テクノロジーを中心に、多岐にわたる領域での重要な動向や技術革新をフォローし、読者に最新の知見を伝えるメディアである。今回は、神経血管疾患の治療におけ [&#8230;]</p>
<p>The post <a href="https://stellanews.life/technology/6477/">J&JがSNIS 2025で片頭痛への塞栓術や新型カテーテルを紹介</a> first appeared on <a href="https://stellanews.life">STELLANEWS.LIFE</a>.</p>]]></description>
										<content:encoded><![CDATA[<article>
  <p>STELLANEWS.LIFE（ステラニュース・ライフ）は、医療、科学、テクノロジーを中心に、多岐にわたる領域での重要な動向や技術革新をフォローし、読者に最新の知見を伝えるメディアである。今回は、神経血管疾患の治療における長年の取り組みと新技術に関するJohnson &#038; Johnsonの発表を紹介する。</p>

  <blockquote>
    <nav>
      <ul class="custom-list">
        <li>Johnson &#038; JohnsonがSNIS 2025で神経血管ケア25年の取り組みと新技術を紹介</li>
        <li>慢性片頭痛への塞栓療法や液体塞栓物質に関連するマイクロカテーテル残留リスクに関する発表が含まれる</li>
        <li>次世代血栓除去カテーテル「CEREGLIDE 42／57」などをStroke Solutionsポートフォリオに追加</li>
      </ul>
    </nav>
  </blockquote>

  <main>
    <p>Johnson &#038; Johnson MedTechは2025年7月14日、神経血管分野における25年の実績を記念し、ナッシュビルで開催される第22回米国神経血管内治療学会（SNIS）年次総会にて、最新の臨床データと技術を紹介すると発表した。発表の中には、TRUFILL n-BCAを用いた慢性片頭痛に対する中硬膜動脈塞栓術の検討や、液体塞栓物質使用時のマイクロカテーテル残留に関する系統的レビューが含まれる。</p>
  </main>

  <ul class="custom-list">
    <li><strong>発表元→</strong>Johnson &#038; Johnson MedTech</li>
    <li><strong>発表日→</strong>2025年7月14日</li>
    <li><strong>発表イベント→</strong>第22回米国神経血管内治療学会（SNIS 2025）</li>
    <li><strong>研究発表①→</strong>TRUFILL n-BCAを用いた中硬膜動脈塞栓術による慢性片頭痛治療（MIGRAINE Study）</li>
    <li><strong>研究発表②→</strong>液体塞栓物質使用時におけるマイクロカテーテル残留率の系統的レビューとメタアナリシス</li>
    <li><strong>注目技術→</strong>血栓除去用次世代カテーテル「CEREGLIDE 42」「CEREGLIDE 57」</li>
    <li><strong>記念事項→</strong>TRUFILL n-BCA製品25周年および研究機関NTI設立10周年</li>
    <li><strong>関連イベント→</strong>ハンズオンラボ、SLICEワークショップ、女性の神経血管治療に関する討論など</li>
  </ul>

  <p><strong>AIによる情報のインパクト評価（あくまで参考として受け取ってください）</strong></p>
  <p>★★★☆☆（★3つで3番目の評価）</p>
  <p>長期にわたる神経血管ケアの技術開発と、その成果に基づく研究成果は評価できるものの、臨床現場での実装や影響は今後の研究進展と実使用結果を待つ必要がある。慢性片頭痛への塞栓療法は新規性があるが、今後の治療標準への定着にはさらなる検証が求められる。</p>

  <footer>
    <h3>参考文献</h3>
    <p>Johnson &#038; Johnson Marks 25 Years of Neurovascular Care with New Innovation Highlights at SNIS 2025<br/>
    <a href="https://www.jnj.com/media-center/press-releases/johnson-johnson-marks-25-years-of-neurovascular-care-with-new-innovation-highlights-at-snis-2025">
    https://www.jnj.com/media-center/press-releases/johnson-johnson-marks-25-years-of-neurovascular-care-with-new-innovation-highlights-at-snis-2025</a></p>
  </footer>
</article>


<figure class="wp-block-image size-medium">
  <img decoding="async" src="https://stellanews.life/wp-content/uploads/2024/03/technology_banner-300x169.webp" alt="" class="wp-image-2933"/>
</figure><p>The post <a href="https://stellanews.life/technology/6477/">J&JがSNIS 2025で片頭痛への塞栓術や新型カテーテルを紹介</a> first appeared on <a href="https://stellanews.life">STELLANEWS.LIFE</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://stellanews.life/technology/6477/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
